Normally gauges and transmitters come in 1/2 " size. I've not seen many 1/2" flanges used. My standard is to have a flanged isolation valve ,1" often with a 2" tee off the main line and a reducer for mechanical integrity, with a tapped blank flange.To Remove or insert a Spacer or Blind you first depressurize the System, Then make it Safe. Then you remove all the Bolts on One (1) side of the Flange set. Then you "Jack" the Flanges apart using the built-In Jack Screws (in the Flanges) or with Flange Spreaders (Look it up). Now with the Flanges spread …The reason is carbon content below 0.03% would be considered 304L per the SA 240 material specification, and limited to 1000 deg F. When you have dual grade certification 304L/304, the 0.04% or higher carbon comes into play for creep strength and one must review the MTR for specific use. SnTMan (Mechanical) 14 … Chemical plant design & operations. (33961 members) forum124 - Professional forum and technical support for engineers for Chemical plant design & operations. Includes problem solving collaboration tools.

MotorCity (Structural) 16 Sep 04 09:48. KarlIt, I would suggest consulting the goal manufacturer to obtain the design loads. The support system will vary among models and manufacturers. This type of loading is not governed by any particular code as it is not a building or structure. That has been my approach for the gymnasium designs in the ...Will and Mango from Part-Time Genius explore the subject of rudeness — why it's dangerous to our health and why we can't stop thinking about it. Advertisement Someone cuts you off ...

Metal and Metallurgy engineering. (45224 members) forum330 - Professional forum and technical support for engineers for Metal and Metallurgy engineering. Includes problem solving collaboration tools. Forum.

Corrosion engineering. (24764 members) forum338 - Professional forum and technical support for engineers for Corrosion engineering. Includes problem solving collaboration tools. Forum. Search. Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... Note that if you select either pinned or fixed, you are departing from reality already, as the connection is unlikely to fit either exactly. So it could be modeled as intermediate in various ways as well. If you neglect deflections in the roof unrelated to this load, you are departing from reality.

See thread507-434895: Tension Field Action - End panels in Old Codes. BA. rb1957 (Aerospace) 7 Sep 20 22:16. the author makes the point that the end bays usually don't have the stiffener at the extreme end of the beam, and so the web cannot develop the shear buckles. In the example R13 posted these end panels aren't doing anything to react the ...

I have modelled a pond with an outlet control structure consisting of a low flow orifice (Flowing to Device 1) and sharp crested weir (Also flowing to Device 1) discharging to a culvert (Modelled as the Primary). The report states that the weir and the orifice are controlling the flows and the culvert passes XXX of XXX …

I think many engineers seem to miss this concept as I have seen many designs with a single hairpin where the hairpin appeared to have been calculated based solely on the area of steel into an un-reinforced slab. hdp321 (Structural) (OP) 6 Mar 23 00:01. There’s about 95 kips of thrust per column. Pats' Pub *. Translation Assistance for Engineers. * Invite-Only Groups that are publicly listed allow you to browse the Group, but you must apply for Group membership before participating in it. Eng-Tips engineering forums is an intelligent work forum community for engineering professionals of all disciplines. ISZ, Thanks for the reply. I contacted the manufacturer and they recommended pointing the arrow toward the sky. The most apparent difference with the orientaion is the voltage output when the cell is loaded. If the arrow is down, the voltage is negative, if pointed up, the voltage is positive.thread404-515636. Dynamo2000 (Mechanical) (OP) 19 Jan 24 21:00. Very recently in the news was an invention called the Holo Tile Floor created by Disney's National Inventors Hall of Fame member Lanny Smoot. This creation allows the user to "walk" in any direction without moving anywhere! The floor shifts to compensate for the user's leg …Mar 2, 2021 · Collaborate with other engineers! Their input will help you overcome mental hurdles and refine your designs. Plus, brainstorming with others is an excellent way to uncover innovative solutions to long-standing engineering issues. A great online resource is eng-tips.com. #13 Over-communicate Stay connected with all the key players in a project. It's defined in chapter 14 for ASCE 7-05 as a wall segment with a horizontal length-to-thickness ratio of at least 2.5, but not exceeding 6, whose clear height is at least two times its horizontal length. Believe the definition in ASCE 7-10 is the same. Essentially a wall pier is a portion of an overall wall that would have a …

Beijing approves the first vaccine of its kind as it looks to jumpstart its flailing economy China has approved a Covid-19 vaccine utilizing MRNA technology for the first time ever... Pats' Pub *. Translation Assistance for Engineers. * Invite-Only Groups that are publicly listed allow you to browse the Group, but you must apply for Group membership before participating in it. Eng-Tips engineering forums is an intelligent work forum community for engineering professionals of all disciplines. To ask an engineering question please visit our forum site at Eng-Tips. Browse our archive of questions and answers below or to access our old forum database of over 10000 questions and answers please visit the old Ask@ forum. Forums; Search; Unanswered; Active Topics; Engineering Questions and Answers: Forums: Topics: Replies: Last Post: …ENG-TIPS. ENG-TIPS stands out as one of the most popular portals for engineer communities on the web, and it’s easy to see why. There are over 18 specific …1 day ago · Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... The current ASME VIII require you to obtain U stamp certification from the ASME Board. They will issue to you, based on extensive testing of your design and fabrication capability, experience and understanding of the current ASME code requirements. No specific PD 5500 requirements. Please note that this month is …

Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register …JAE (Structural) 9 Feb 11 21:01. Sounds like you got it. wannabeSE (Civil/Environmental) 9 Feb 11 21:13. If you are anchoring the equipment to masonry or concrete, look at ASCE 7-05 section 13.4.2. You may need to multiply the seismic force by 1.3. Also, if the anchors are not prequalified for seismic, you may need to …

Finite Element Analysis (FEA) engineering. (36618 members) forum727 - Professional forum and technical support for engineers for Finite Element Analysis (FEA) engineering. Includes problem solving collaboration tools. Forum. Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... Too much deflection could possibly induce untoward actions on the part of the person falling; if the railing, say, deflected a foot, that might cause the person to try and do something that might cause them additional, or unexpected, harm, as opposed to a railing that only deflected, say, half an inch.Product Guide Directory. Learn About Each of Eng-Tips' Industrial & Technology Marketing Solutions. Grow Brand Awareness. Build Purchase Intent. Generate Leads. Access The …Foundation engineering. (26096 members) forum256 - Professional forum and technical support for engineers for Foundation engineering. Includes problem solving collaboration tools. Forum. Search.In ASCE 7-22, partially open is included in those. My assumption is that they messed up and forgot to include it in ASCE 7-16. My tin-foil hat opinion: Partially open was added simply because we aren't comfortable labeling buildings that are THAT "open" as "enclosed."UcfSE (Structural) 29 Nov 06 21:52. A good limit for live load deflection is 3/4-inch. You don't want to squash your interior partitions either, besides just the windows and such in the exterior walls. Some manufacturers have products designed to go allow more than 3/4 inches of deflection but it isn't the norm.

The underlying soils are saturated clayey sand soils (SC). The fill material is a slightly silty sand (-200=12 to 15%) with a modified proctor of 119 pcf and 11% moisture. We have two feet of fill in above the wet clayey soils (SC). The fill material was tested to be at 96 to 98% compaction of the modified proctor …

I have modelled a pond with an outlet control structure consisting of a low flow orifice (Flowing to Device 1) and sharp crested weir (Also flowing to Device 1) discharging to a culvert (Modelled as the Primary). The report states that the weir and the orifice are controlling the flows and the culvert passes XXX of XXX …

Corrosion engineering. (24764 members) forum338 - Professional forum and technical support for engineers for Corrosion engineering. Includes problem solving collaboration tools. Forum. Search. Qatar has for months been criticized for mistreating migrant workers. Qatar, one of the world’s richest countries and the winner of the bid to host the soccer World Cup in 2022, ha...1 day ago · Join Eng-Tips ® Today! Join your peers on the Internet's largest technical engineering professional community. It's easy to join and it's free. Here's Why Members Love Eng-Tips Forums: Talk To Other Members; Notification Of Responses To Questions; Favorite Forums One Click Access; Keyword Search Of All Posts, And More... Register now while it ... Activities. Civil/Environmental engineering general discussion. Climate Change Engineering Solutions. Earthwork/grading engineering. Soil/Groundwater environmental engineering. Storm/Flood engineering. Surveying & Geomatics. Traffic Engineering. Waste disposal & treatment. In linear analysis, starting from displacements, the nodal forces can be calculated in two equivalent ways: a) R_e = K_e * U_e. b) At each integration point, calculate strains using B (m) * U_e, calculate stresses using C*e, then integrate stresses using Eq. 4.29. R_e: element nodal force.Jan 3, 2021 · PE Civil Structural Exam Study Advice9. Hello All! I am preparing to take the PE Civil Structural exam for the first time in October 2021. Please reply with what each of you used to study and pass the exam. I have found a lot of engineers who recommend the CERM book and NCEES Civil Structural Practice Exam book. Existing 2 storey 40+ yr old house all walls as 4" brick exterior with 4" block backup, with bond bricks turned every 7th course. I believe that this is considered as an 8" masonry bearing wall...not 4" load bearing block with 4" veneer. The building depts around are extremely quick to call out 'brick veneer' can't be used for connecting or ... Eng-Tips Forums is an English-language knowledge market website that allows users to post engineering-related questions to be answered and answer questions asked by other users. The targeted audience of Eng-Tips is engineering professionals. smokiibear (Civil/Environmental) (OP) 10 Jan 20 17:08. I'm refering to the specific wording in 7-16, chp 28. Also, I have two structures that will combine to make 1. When the roof is off, I have walls with no roof, and I have a roof with no walls. The roof will slide to another structure without walls, just columns.Mar 2, 2021 · Collaborate with other engineers! Their input will help you overcome mental hurdles and refine your designs. Plus, brainstorming with others is an excellent way to uncover innovative solutions to long-standing engineering issues. A great online resource is eng-tips.com. #13 Over-communicate Stay connected with all the key players in a project. Happy Friday. Looking at replacing the entire bottom of a 60' diameter tank. Given the foundation configuration and some other challenges, the recommended solution is to install a second bottom over the existing bottom as specified in API 653 9.10.2. Looking for a couple bench marks from members. - Confirmation there isn't an API-653 standard ...Antenna & propagation engineering. Circuit design. Communication & signal processing engineering. Electric motors & generators engineering. Electric power & transmission & distribution. Electrical Engineering general discussion. Microwave & electromagnetic engineering. Power supply & electronic component design.

Ayurveda. Unani. Homeopathy. Cowpathy. You’ve heard of ayurveda, the traditional Indian medical science. So have you about Unani, the Perso-Arabic healing science. Then there is ho...Chemical process engineering. (26899 members) forum798 - Professional forum and technical support for engineers for Chemical process engineering. Includes problem solving collaboration tools. Forum.Note that if you select either pinned or fixed, you are departing from reality already, as the connection is unlikely to fit either exactly. So it could be modeled as intermediate in various ways as well. If you neglect deflections in the roof unrelated to this load, you are departing from reality.*Eng-Tips's functionality depends on members receiving e-mail. By joining you are opting in to receive e-mail. Posting Guidelines. Promoting, selling, recruiting, coursework and thesis posting is forbidden. Students Click Here. Eng-Tips Posting Policies Contact US. Home > Forum Areas Chemical Engineers Area. Only the top forums under each heading is …Instagram:https://instagram. terraria baits12 30 pm gmthairy man in genesis crossword clueamazon t mobile unlocked phones U.S. stocks traded higher this morning, with the Dow Jones gaining more than 100 points on Friday. The Dow traded up 0.41% to 33,473.16 while the... U.S. stocks traded higher this... retrojunk.com7 little words march 15 2023 In B31.3, there is reference to hardness testing in accordance with 333.1.7., see below. 331.1.7 Hardness Tests. Hardness tests of production. welds and of hot bent and hot formed piping are. intended to verify satisfactory heat treatment. The hardness. limit applies to the weld and to the heat affected. shylily chaturbate Safety Relief Valve engineering (PSV) (8427 members) forum1203 - Professional forum and technical support for engineers for Safety Relief Valve engineering (PSV). Includes problem solving collaboration tools. Forum. Eng-Tips Groups Engineering Language/Grammar Skills Engineers with Hobbies Local Exhaust Ventilation NICET Certification, training and education Pats' Pub Translation Assistance for Engineers. People Aeronautics & Space Engineers Activities Aeronautic & Space engineering general discussion Aircraft engineering Rotorcraft engineering …Mar 22, 2023 · From reading XR250s posts I think this is how he approaches it as well. 3. YoungGunner (Structural) 23 Mar 23 15:22. Having worked in residential for 7 years now, I have a few thoughts on the matter: First off, the IRC already shows questionable engineering compared to our "big boy" design standards/codes.