Mcquay model number tonnage.

2 McQuay Enfinity Water Source Heat Pumps Catalog 1100 Introduction McQuay Air Conditioning plant with over 450,000 square feet of manufacturing space - located in Auburn, New York McQuay Enfinity™ Water Source Heat Pumps More than 30 years ago, McQuay designed the first com-plete line of water source heat pumps for high efficiency, in-

Mcquay model number tonnage. Things To Know About Mcquay model number tonnage.

Resetting Cooling and Heating Lockouts. 25. Maintenance. 27. Warranty. 29. Advertisement. Trane TTA180C series Pdf User Manuals. View online or download Trane TTA180C series Installation Operation & Maintenance.A ton of air conditioning equals 12,000 BTU, and 60 divided by 12 equals 5, so the data plate below indicates the system is 5 tons. Here's a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 - 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, and 60 = 5 tons. Unfortunately, Rheem sometimes varies from the standard that ...1998 McQuay Air Cooled Liquid Chiller- 204 Ton. Model: ALS204AS12. S/N: 58G8128101. Refrigerant: R-22. Maximum relief pressure: 450 psig. Design pressure hi/lo: 450/150 psig. System requirements: 208 V, 881 amps, 60 Hz, 3 phase. (2) McQuay Screw Compressors, Models: SAL175RA13DA and SA175BA13DA, S/N's: 52ER7027-10 andSerial Number- February, 1999 and later. AUB U 99 05 00148. Plant Identification Abbreviation. AUB = Auburn. U= Unit. Serial Number (build sequence) Week of Manufacture. Year of Manufacture. 08= 2008. 09= 2009 etc. WSHP; WCAX1,2, WCDX1,2, WCMS1,2 Size 019 Designs A, B Rev. J 01/16 RPL 1105106 / Page 4. Nomenclature. Model Number. WCDS 2 019 E Z ...

800.438.8898. Find genuine OEM McQuay Fan & Blower Motors at Parts Town with the largest in-stock inventory and same day shipping until 9pm ET.Model AGZ 026Bthrough AGZ 130B Two-Circuit Chiller (4-Fan Model Illustrated) Model AGZ 010A through AGZ 034A, Single Circuit Chiller Cover Pictures: The upper unit is a Model AGZ 034A, 34 ton chiller. The lower unit is a Model AGZ 130B, 130 ton chiller with the end protective guard removed in order to view the unit interior. “W” Shaped Coil

Model: The Unit Model Number: Note- It is very important to remember that the AAF and HermanNelson model numbers differ from all the other brand names listed in the index in that the model number is located in the middle of the alpha/numeric model number string. (Example: SPAGAAPFCWG53211000. The bold letters indicate the model number.

You can determine the size in tons of your Tempstar HVAC system by examining the model number on the data plate at the side of the condenser (outdoor unit). Look for two numbers in the middle of the model number that are divisible by 6 or 12, and represent the nominal BTU of the system in thousands. A ton of air conditioning equals 12,000 BTU ...Page 36 3-1/2 x No. of DX rows *DX coil configuration (S = Standard, L = Large) is identified by the 8th digit of the RPS/RDT or RFS model number, found on the unit nameplate. For example, DX = L for unit model number RFSO6OCLY. Page 37: Refrigeration Service Valves The unit is shipped with all refrigeration service valves closed.5 Tons = 60,000 BTU = 3,000 sq. feet (Model: RACCZR060) You can also manually compute the AC size based on the measurement of the area to be cooled. On average you'll need 0.0016 tons of AC per square foot. For instance, your house is 600 square feet. Multiply 600 by 25 BTU, and the product is 15,000.The Condensing Unit for Applied Rooftop and Air Handler Systems. The McQuay RCS air cooled, remote condenser offers a wide selection of nominal capacities from 25 to 135 tons. Units are designed for quiet and energy efficient operation meeting ASHRAE 90.1 efficiency requirements. Dual circuits with scroll compressors from 25 to 105 tons with ...Obsolete Brand (1994) How to determine the date of production/manufacture or age of Snyder General® HVAC Systems. The date of production/manufacture or age of Snyder General® HVAC equipment can be determined from the serial number located on the data plate.

Application Capacity. Application Capacity is capacity associated with a nominal 10°F TD, 25°F/-20°F SST application condition historically established to successfully size equipment and components to satisfy a heat load, net of all influences, in an application. Enter your legacy model number. Lookup New Equivalent Model.

cookies collecting statistics about traffic and users' behavior on our or third party websites

Manuals and User Guides for McQuay PEH063. We have 1 McQuay PEH063 manual available for free PDF download: Operating And Maintenance Data.260 TON McQuay Centrifugal Water Chiller Model PEH063. Share via Email Print Listing. 260 TON McQuay Centrifugal Water Chiller Model PEH063. Request A Quote or Call (817) 563-2571. ... Stock Number: 21052: Material: Oilseed: Quantity: 1.0: Location: Fort Worth, TX: Contact Us. 4760 Freeman Drive Fort Worth, Texas 76140 (817) 563-2571.We can determine the nominal size of Luxaire furnace system by examining the model number. Tonnage is a measure of BTU's in 12,000 BTU increments. For example a 1 ton system would have 12,000 BTU's. A 2.5 ton system would have 30,000 BTU's. From the Luxaire furnace model number above, with the effeciency rating (AFUE) 80%.Model DPS. Upgrade your HVAC system and join the Rebel revolution - the ultimate solution for industry-leading performance and climate-controlled comfort. With Rebel’s new 3-31 ton heat pump design, you can enjoy year-round heating and cooling, even in freezing temperatures as low as -10°F. Remove reliance on fossil fuel and capitalize on a ...Enfinity console water source heat pumps (WSHP), from 1/2 to 1-1/2 tons, are designed for high-efficiency, individually-zoned comfort control in offices, schools, assisted living facilities, manufacturing buildings, and a variety of commercial applications. Using ozone-friendly R-410A refrigerant, Enfinity's quiet, high performance and ...

McQuay Airmatic Air Cooled Chiller 175 Ton, 1995 model,Model ALR175C, S/N 5ZM8178401. Barrel information: year 1994, Model E1610, S/N 52M0003700, 6-1/2 in. outlet on barrel. (4) compressors, 50 hp, 83 rla, 535 lra, 460 volt, 60hz, 3ph. Overall dimensions 7ft. 5 in. x 22 ft. 6 in. x 7 ft.McQuay 6- to 10-ton horizontal units have a common cabi-net size and common water, condensate, and duct connection locations for easier and more efficient installation. The cabinet is constructed of unpainted, G-60 galvanized steel. Large panels provide access to the fan/motor compart-ment and the compressor/control compartment. The interiors of2004 McQuay Air Cooled Chiller 130 Ton. Model AGZ-130BS. S/N STNE04109521, 460 /60/3. This chiller is factory new used only for in house testing. Has 6 scroll compressors and is capable of producing glycol at 0 F.Ruby: 972-777-6574. Jamey: 214-755-8019. [email protected]. Our Location. Our main service facility is located in Dallas, Texas. We ship anywhere in the United States, Mexico, Canada, South America and Internationally. Surplus Group. 2121 Santa Anna Ave. Suite 100.A ton of air conditioning equals 12,000 BTU, and 48 divided by 12 equals 4, so the data plate below indicates the system is 4 tons. Here's a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 - 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, and 60 = 5 tons. If you are unsure whether you have found the right two ...McQuay R-410A condensing units are available with EERs that exceed ASHRAE 90.1-2004. R-407C inevitably forces the unit to be significantly less efficient or more expensive, while R-410A reduces energy costs. R-410A refrigerant components are always evenly mixed, which is not true for R-407C.McQuay Offers the Widest Choice of ARI Certified, Ozone Safe Centrifugal Chillers NOTE: The upper capacity limit for ARI certification for water-cooled chillers is 2,500 tons. …

Summary of Contents for McQuay AGZXXXBS Series. Page 1 Installation, Operation and Maintenance Manual IOMM AGZ-5 Group: Chiller Part Number: 330411801 Effective: October 2004 Supercedes: IOMM AGZ-4 Air-Cooled Scroll Compressor Chiller AGZ 026B through 130B 60 Hertz, R-22...

A ton of air conditioning equals 12,000 BTU so, for the model number 4AC18LT 24 P, 24 divided by 12 equals 2 tons. Another example is RHP13A48F, which is 4 tons. And this example is 2-1/2 tons. Here's a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 - 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, and 60 = 5 tons.Page 1 Installation, Operation, IOM 1210-1 and Maintenance Manual Group: Chiller Part Number: IOM1210-1 Date: August 2014 Magnitude ® Magnetic Bearing Centrifugal Chillers Model WMC, C Vintage 125 to 400 Tons (440 to 1400 kW) HFC-134a Refrigerant 50/60 Hz...; Page 2: Table Of Contents ©2014 Daikin Applied. Illustrations and data cover the Daikin Applied product at the time of publication and ...McQuay Airmatic Air Cooled Chiller 175 Ton, 1995 model,Model ALR175C, S/N 5ZM8178401. Barrel information: year 1994, Model E1610, S/N 52M0003700, 6-1/2 in. outlet on barrel. (4) compressors, 50 hp, 83 rla, 535 lra, 460 volt, 60hz, 3ph. Overall dimensions 7ft. 5 in. x 22 ft. 6 in. x 7 ft.HVAC units are identified by their multiple-character model number that identifies a particular type of unit. Below you will find a partial explanation of the alphanumeric identification code (aka Model Number Nomenclature). Our samples have been simplified to concentrate more on the location of each individual units tonnage and air flow ...MicroTech SmartSource Controller with BACnet®Communication Module. Daikin water source heat pumps are available with a BACnet MS/TP communication module that is designed to communicate over a BACnet MS/TP communications network to a building automation system (BAS) . It can be factory or field-installed.Daikin Applied RoofPak® RPS (15-140 Tons) Design flexibility, energy efficiency, system performance and reliability make Daikin RoofPak® applied rooftop systems the ideal solution for your one to eight-story building projects. Available in air-cooled and evaporative-cooled models, with capacities from 15 to 150 tons, they combine the lower ...McQuay was founded in the United States in 1933 and has been supplying and servicing equipment for air conditioning, heating and ventilation systems, as well as manufacturing radiators and heat exchangers. ... I also don't have the full model number on the sticker so its difficult to find. Anything will help thank you! chad M/N - LCA150 SM S/N ...

Flush the system water piping thoroughly before making connections to the unit evaporator. Install a 40-mesh strainer in the inlet pipe to the chiller. Design the water piping so the chilled water circulating pump discharges into the evaporator inlet. Connect the return water line to the evaporator inlet connection.

Below: McQuay rooftop unit model number decoder. Below: Snyder General or McQuay rooftop unit CUR model nomenclature decoder. Below: more Snyder General or McQuay installation or operating manuals. Snyder General McQuay CUR-Series 075-150 ROOFTOP UNIT MANUAL [PDF] (1993) Models CUR075G through CUR 150G

McQuay ALS250AS27-ER10 I need the manual and service literature, thanks!! Reply . 10-01-2013, 07:54 PM #2. freonrick. View Profile View Forum Posts ... The model number is AGS351DP27NN-ER10, the compressors are HSA205QY13YA, thanks!! Reply . Quick Navigation Chillers Open Forum Top. Site Areas; Settings; Private Messages;The first way to calculate tonnage is to just multiply the number of square feet of your room by 0.0016. This will give you AC tonnage value in no time. Suppose you are going to buy an air conditioner for 600 sq ft area, you can calculate AC tonnage by: AC Tonnage = (Area of Room in Square Feets) * 0.0016 tons/sq ft.Trane TTA180C series Installation Operation & Maintenance (32 pages) Split System Cooling Condensers 7 1/2 - 20 Tons. Brand: Trane | Category: Air Conditioner | Size: 2.63 MB. Table of Contents. Table of Contents. 3.To identify the tonnage of your RHEEM air conditioner or heat pump, you can read the model number. Look for those elusive two digits in the model number. The size is usually divided by 24, 36, 42, or 60. This number represents the nominal BTU of the system in thousands. The number to remember is 12,000 BTU's or, more simply, 12. Find Us. McQuay Air-conditioning Limited (+852) 2893 6261; Unit 901~905, 9/F,Elite Centre, 22 Hung To Road, Kwun Tong, Kowloon,Hong Kong [email protected]. 817-229-3171. North Texas Office: Dan @ 817-966-5350. South Texas Office: Mike @ 210-413-3333. This Used McQuay 110 Ton Air Cooled Chiller has been inspected and is located in our facility in Bridgeport, Tx. We Buy and We Sell New and Used Chillers, Cooling Towers and Equipment. McQUAY CENTRIFUGAL OPERATING LOG. .23 McQUAY SERVICE PROGRAMS 24.17, 18 18 18 18 18 18 19 19 INTRODUCTION GENERAL DESCRIPTION The McQuay Model PEH Centrifugal Water Chillers are com-plete, self-contained, automatically controlled water chilling units. Each unit is completely assembled and factory tested prior to shipment. Daikin McQuay Packaged System Nominal capacity 006 = 6 tons 007 = 7.5 tons 010 = 10 tons 012 = 12 tons Design vintage A = Vintage 1 Cooling efficiency H = High (exceeds ASHRAE 90.1) Line voltage 2 = 208 volt power supply 3 = 230 volt power supply 4 = 460 volt power supply 5 = 575 volt power supply Heat medium Y = None (cooling only)HVAC Guide Specifications. Air-Cooled Liquid Chiller Nominal Size: 5 Tons. Multiaqua Model Number: MAC060-01 N. Part 1-General 1.01 System Description. Multiaqua air-cooled liquid chillers are designed using scroll compressors, low sound condenser fans and high efficiency pumps. 1.02 Quality Assurance.Buick car models come in all shapes and price ranges. See pictures and learn about the specs, features and history of Buick car models. Advertisement Buick models come in all shape...The date of production/manufacture or age of AAF brand HVAC equipment can be determined from the serial number located on the data plate. Note: Traditional heating and cooling systems no longer manufactured under AAF or AAF-McQuay brand names. Parent Company: AAF International and AAF-Flanders, a subsidiary company of Daikin Industries.CALGARY, Alberta, Feb. 08, 2021 (GLOBE NEWSWIRE) -- The Board of Directors of Computer Modelling Group Ltd. ('CMG' or the “Company”) announces a... CALGARY, Alberta, Feb. 08, 202...

2000 McQuay Air Cooled Chiller-350 Tons. Model: ALS370BS-27ER10. S/N: STNU000600277. Refrigerant R-22, max pressure 300 psi. Power supply 460V, 60Hz, 3phase. (24) Condenser fans, 2.0 HP motor, 28 in. dia.1140 rpm, 60 Hz. High efficiency fin and tube type condensers with integral sub cooler, (12) fins per in. and 4 rows2. Locate the Serial Number on the tag. It probably just says "Serial," before the number. Decode the Carrier Serial Number - 9 and 10 Digits. OK, now here is how to read a Carrier AC serial number - or the number on a heat pump or furnace. 1. The first two numbers refer to the week of the year. 01 is the first week in January. 52 is ...1998 McQuay Air Cooled Chiller - 204 Ton Mfg: McQuay Model: ALS204AS12 Stock No. PSL01.15 Serial No. 58G8128101 1998 McQuay Air Cooled Liquid Chiller- 204 Ton. Model: ALS204AS12. S/N: 58G8128101. Refrigerant: R-22. Maximum relief pressure: 450 psig. Design pressure hi/lo: 450/150 psig. System requirements: 208 V, 881 amps, 60 Hz, 3 phase.Instagram:https://instagram. directtv hallmark channelleap 2025 algebra 1 practice test pdffinn sweeney momfree llewellyn tarot be seen that a Model MC216 UI1it will deliver 6550 CFM with a fan outlet velocity of 1605 FPM and that the cooling coil face velocity will be 500 FPM. 2. From the General Specifications Table on Page 11 it is found that the maximum number of zones is 12 for a Model MC216 unit. Each available zone in a McQuay Multi-Zone unit eugenia cooney obituaryhow to pair xfinity remote to tv without code ner on the main control box door. It includes the unit model number, serial number, unit part number, electrical character-istics, and refrigerant charge. Compressor Nameplate On units with a single compressor on each circuit, the com-pressor will include one compressor nameplate. On units that utilize the tandem compressor design, eachPart Number: 910131165. Date: May 2012. IM 1049-3. Daikin McQuay ® Enfinity ™ Horizontal Water Source Heat Pumps R-410A Refrigerant. Model CCH, CCW Unit Sizes 007 – 070 ©2012 McQuay International • 800.432.1342 • www.daikinmcquay.com rc willey sacramento products Specific Inspection Topics Inspecting HVAC Systems. mbruchs (Michael Bruchs) August 6, 2014, 3:17am 1. Inspected a 1967 condominium with a McQuay Inc air handler (manufactured in Minneapolis), model number SVD-81-U with serial number V 110, used for both cooling and heating. The cooling system was functional during the inspection.15- and 20-Ton Packaged Ultra-High-Effi ciency Rooftop Performance Data (Gas or Electric Heat) Nominal Size (tons) 15 20 Effi ciency Ultra-High Ultra-High Model Number LCH/LGH 180U4M LCH/LGH 240U4M Blower Type MSAV - Belt Drive MSAV - Belt Drive Net Cooling Capacity (Btuh) 180,000 234,000 Cooling Stages (up to) 4 4 Nominal Supply Air (cfm ...